J Biol Chem 2014 Dec 19;28951:35438-54. doi: 10.1074/jbc.M114.612713.
Show Gene links Show Anatomy links

Temperature and voltage coupling to channel opening in transient receptor potential melastatin 8 (TRPM8).

Raddatz N , Castillo JP , Gonzalez C , Alvarez O , Latorre R .


???displayArticle.abstract???
Expressed in somatosensory neurons of the dorsal root and trigeminal ganglion, the transient receptor potential melastatin 8 (TRPM8) channel is a Ca(2+)-permeable cation channel activated by cold, voltage, phosphatidylinositol 4,5-bisphosphate, and menthol. Although TRPM8 channel gating has been characterized at the single channel and macroscopic current levels, there is currently no consensus regarding the extent to which temperature and voltage sensors couple to the conduction gate. In this study, we extended the range of voltages where TRPM8-induced ionic currents were measured and made careful measurements of the maximum open probability the channel can attain at different temperatures by means of fluctuation analysis. The first direct measurements of TRPM8 channel temperature-driven conformational rearrangements provided here suggest that temperature alone is able to open the channel and that the opening reaction is voltage-independent. Voltage is a partial activator of TRPM8 channels, because absolute open probability values measured with fully activated voltage sensors are less than 1, and they decrease as temperature rises. By unveiling the fast temperature-dependent deactivation process, we show that TRPM8 channel deactivation is well described by a double exponential time course. The fast and slow deactivation processes are temperature-dependent with enthalpy changes of 27.2 and 30.8 kcal mol(-1). The overall Q10 for the closing reaction is about 33. A three-tiered allosteric model containing four voltage sensors and four temperature sensors can account for the complex deactivation kinetics and coupling between voltage and temperature sensor activation and channel opening.

???displayArticle.pubmedLink??? 25352597
???displayArticle.pmcLink??? PMC4271229
???displayArticle.link??? J Biol Chem


Species referenced: Xenopus laevis
Genes referenced: trpm8

References [+] :
Almers, Gating currents and charge movements in excitable membranes. 1978, Pubmed