Mikrochim Acta 2024 Oct 05;19111:648. doi: 10.1007/s00604-024-06685-7.
Show Gene links Show Anatomy links

Detection of pathogenic gram-negative bacteria using an antimicrobial peptides-modified bipolar electrode-electrochemiluminescence platform.

Ji L , Wang F , Qi Y , Qiao F , Xiong X , Liu Y .


???displayArticle.abstract???
Real-time, label-free detection of gram-negative bacteria with high selectivity and sensitivity is demonstrated using a bipolar electrode-electrochemiluminescence (BPE-ECL) platform. This platform utilizes anode luminescence and cathode modification of antimicrobial peptides (AMPs) to effectively capture bacteria. Magainin I, basic AMP from Xenopus skin, boasting an α-helix structure, exhibits a preferential affinity for the surface of gram-negative pathogens. The covalent attachment of the peptide's C-terminal carboxylic acid to the free amines of a previously thiolated linker ensures its secure immobilization onto the surface of the interdigitated gold-plated cathode of BPE. The AMP-modified BPE sensor, when exposed to varying concentrations of gram-negative bacteria, produces reproducible ECL intensities, allowing for the detection of peptide-bacteria interactions within the range 1 to 104 CFU mL-1. Furthermore, this AMP-modified BPE sensor demonstrates a selective capacity to detect Escherichia coli O157:H7 amidst other gram-negative strains, even at a concentration of 1-CFU mL-1. This study underscores the high selectivity of Magainin I in bacterial detection, and the AMP-modified BPE-ECL system holds significant promise for rapid detection of gram-negative bacteria in various applications. The AMP-modified BPE sensor generated reproducible ECL intensity that detected peptide-bacteria interactions in the range 1 to 104 CFU mL-1. The AMP-modified BPE sensor also selectively detected E. coli O157:H7 from other gram-negative strains at a concentration of 1-CFU mL-1. In this paper, AMP demonstrated high selectivity in bacterial detection. The AMP-modified BPE-ECL system prepared has a great potential for application in the field of rapid detection of gram-negative bacteria.

???displayArticle.pubmedLink??? 39367972
???displayArticle.link??? Mikrochim Acta
???displayArticle.grants??? [+]

Genes referenced: magainins