Xenbase Image ID: 169125


Figure 7. In-series connected resistance model. The conduction pathway was divided into five resistors connected in-series: the external and internal access resistances, RAccIn and RAccEx, respectively; the resistance of the section occupied by sucrose, RSucOc; the resistance of the sucrose-free section, RSucFr; and the selectivity filter, Rf. See Table 2 for details of resistance calculations.

Image published in: Díaz-Franulic I et al. (2015)

© 2015 Díaz-Franulic et al. Creative Commons Attribution-NonCommercial-ShareAlike license